• Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter
  • Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter
  • Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter

Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter

After-sales Service: Online Technical Support
Warranty: One Year
Display: Digital
Portable: Portable
Appliance: Biochemistry
Certification: ISO9001, CE
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
BT900P
pH Range
-2.00 ~ 20.00pH
Resolution
0.001, 0.01, 0.1pH, Selectable
Accuracy
±0.002pH
pH Buffer Options
USA, Nist, DIN, 2 Custom Buffers
ORP Range
±1999mv
ORP Resolution
0.1, 1mv, Selectable
ORP Accuracy
±0.2mv
Measurement Modes
Relative or Absolute Mv
Measurement Units
Ppm, Mg/L, Mol/L, Mmol/L
Dissolved Oxygen Range
0.00 to 20.00mg/L
Do Resolution
0.01, 0.1mg/L, Selectable
Transport Package
Standard Export Package
Specification
-2.00 ~20.00 pH
Trademark
WEST TUNE
Origin
China
HS Code
9026809000
Production Capacity
200PCS

Product Description

Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter

Multiparameter portable pH meter contains 8 measurement modes, the meter is suitable for measuring the pH, ORP, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity and dissolved oxygen.

Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter

Features
• Professional portable pH/ion meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and offset.

Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Direct ion concentration readout simplifies the measurement process.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.
Bt 900p Portable pH/Conductivity/Dissolved Oxygen Meter

Ion Concentration Mode:
• 2 to 5 points calibration, including the 8 concentration points can be selected.
• Direct ion concentration readout simplifies the measurement process.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
  and pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement error.

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Auto-Power Off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature
  unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to PC.
• Multi-mode power scheme (batteries, power adapter and USB port) ensures that using the
  meter smoothly.


Specifications

Model

Bante900P

   pH

 

   Range

-2.000 to 20.000pH

   Resolution

0.001, 0.01, 0.1pH, selectable

   Accuracy

±0.002pH

   Calibration Points

1 to 5 points

   pH Buffer Options

USA, NIST, DIN, 2 custom buffers

   ORP

 

   Range

±1999.9mV

   Resolution

0.1, 1mV, selectable

   Accuracy

±0.2mV

   Calibration Points

1 point

   Measurement Modes

Relative or absolute mV

   Ion Concentration

 

   Range

0.001 to 19999 (deponding on the range of ISE)

   Resolution

0.001, 0.01, 0.1, 1

   Accuracy

±0.5% F.S. (monovalent), ±1% F.S. (divalent)

   Calibration Points

2 to 5 points

   Calibration Solutions

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000

   Measurement Units

ppm, mg/L, mol/L, mmol/L

   Conductivity

 

   Range

0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

   Resolution

0.001, 0.01, 0.1, 1

   Accuracy

±0.5% F.S.

   Calibration Points

1 to 5 points

   Calibration Solutions

10µS, 84µS, 1413µS, 12.88mS, 111.8mS

   Temperature Coefficient

Linear (0.0 to 10.0%/°C), pure water

   Reference Temperature

20/25°C

   Cell Constant  

K=0.1, 1, 10 or custom

   TDS

 

   Range

0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt

   Resolution

0.01, 0.1, 1

   Accuracy

±1% F.S.

   TDS Factor

0.1 to 1.0 (default 0.5)

   Salinity

 

   Range

0.00 to 80.00ppt, 0.00 to 42.00psu

   Resolution

0.01

   Accuracy

±1% F.S.

   Resistivity

 

   Range

0.00 to 20.00MΩ

   Resolution

0.01

   Accuracy

±1% F.S.

   Dissolved Oxygen

 

   DO Range

0.00 to 20.00mg/L

   Resolution

0.01, 0.1mg/L, selectable

   Accuracy

±0.2mg/L

   % Saturation of Oxygen

0.0 to 200.0%

   Resolution

0.1, 1%, selectable

   Accuracy

±2.0%

   Calibration Points

1 or 2 points

   Pressure Correction

60.0 to 112.5kPa/450 to 850mmHg, manual

   Salinity Correction

0.0 to 50.0g/L, manual

   Temperature

 

   Range

0 to 105°C/32 to 221°F

   Resolution

0.1°C/0.1°F

   Accuracy

±0.5°C/±0.9°F

   Offset Calibration

1 point

   Calibration Range

Reading ±10°C

   General Specifications

 

   Temperature Compensation

0 to 100°C/32 to 212°F, manual or automatic

   Stability Criteria

Low or high

   Calibration Due Alarm

1 to 31 days or off

   Auto-Power Off

10, 20 or 30 minutes after last key pressed

   Memory

Stores up to 500 data sets

   Output

USB communication interface

   Connector

BNC, 6-pin nimi-DIN, 3.5mm jack socket

   Display

Custom LCD (80×60mm)

   Power

3×1.5V AA batteries or DC5V power adapter

   Battery Life

Approximately 150 hours (turn off the backlight)

   Dimensions

170(L)×85(W)×30(H)mm

   Weight

300g


Optional Accessories
P11 pH Electrode For the general applications
P11-LiCl pH Electrode For the non-aqueous samples
P11-HA pH Electrode For the high alkalines samples
P11-NA pH Electrode For the biofuels
P12 pH Electrode For the sample in the test tube
P13 pH Electrode For the micro-volume samples
P15 pH Electrode For the low conductivity samples
P16 pH Electrode For the Tris buffers
P18 pH Electrode For the slurries and soils
P19 pH Electrode For the semisolids
P21 pH Electrode For the colloids
P22 pH Electrode For the high temperature samples
501 ORP Electrode For the sample with strong redox potential
502 ORP Electrode For the sample with weak redox potential
Na-US Sodium Electrode Range: 0.1 to 23000ppm
CL-US Chloride Electrode Range: 1.8 to 35500ppm
F-US Fluoride Electrode Range: 0.02ppm to saturation
Ca-US Calcium Electrode Range: 0.02 to 4000ppm
NO3-US Nitrate Electrode Range: 0.4 to 62000ppm
Br-US Bromide Electrode Range: 0.4 to 79900ppm
NH4-US Ammonium Electrode Range: 0.1 to 18000ppm
Cn-US Cyanide Electrode Range: 0.2 to 260ppm
Cd-US Cadmium Electrode Range: 0.01 to 11200ppm
Cu-US Copper Electrode Range: 0.006 to 6400ppm
I-US Iodide Electrode Range: 0.06 to 127000ppm
Pb-US Lead Electrode Range: 0.2 to 20700ppm
Ag-US Silver Electrode Range: 0.01 to 107900ppm
K-US Potassium Electrode Range: 0.04 to 39000ppm
S-US Sulphide Electrode Range: 0.003 to 32100ppm
NH3-US Ammonia Electrode Range: 0.02 to 17000ppm
CON-0.1 Conductivity Electrode For the pure water
CON-1 Conductivity Electrode For the general water
CON-10 Conductivity Electrode For the high conductivity water
DO100 Dissolved Oxygen Electrode For the DO and % saturation measurements
DO Membrane Cap For the dissolved oxygen electrode
DO Electrolyte Solution For the dissolved oxygen electrode
TP-10K Temperature Probe For the temperature measurement
pH Buffer Solutions 480ml/bottle
Conductivity Standard Solutions 480ml/bottle
Ion Standard Solutions 480ml/bottle
Ionic Strength Adjuster 480ml/bottle

About us
Bt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen MeterBt 900p Portable pH/Conductivity/Dissolved Oxygen Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now