Customization: | Available |
---|---|
After-sales Service: | Online Technical Support |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Multiparameter portable pH/conductivity meter contains 6 measurement modes, the meter is suitable for measuring the pH, ORP, conductivity, total dissolved solids (TDS), salinity and resistivity.
Model |
Bante901P |
pH |
|
Range |
-2.000 to 20.000pH |
Resolution |
0.001, 0.01, 0.1pH, selectable |
Accuracy |
±0.002pH |
Calibration Points |
1 to 5 points |
pH Buffer Options |
USA, NIST, DIN, 2 custom buffers |
mV |
|
Range |
±1999.9mV |
Resolution |
0.1, 1mV, selectable |
Accuracy |
±0.2mV |
Conductivity |
|
Range |
0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
Resolution |
0.001, 0.01, 0.1, 1 |
Accuracy |
±0.5% F.S. |
Calibration Points |
1 to 5 points |
Calibration Solutions |
10µS, 84µS, 1413µS, 12.88mS, 111.8mS |
Temperature Coefficient |
Linear (0.0 to 10.0%/°C), pure water |
Reference Temperature |
20/25°C |
Cell Constant |
K=0.1, 1, 10 or custom |
TDS |
|
Range |
0.00 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution |
0.01, 0.1, 1 |
Accuracy |
±1% F.S. |
TDS Factor |
0.1 to 1.0 (default 0.5) |
Temperature |
|
Range |
0 to 105°C/32 to 221°F |
Resolution |
0.1°C/0.1°F |
Accuracy |
±0.5°C/±0.9°F |
Offset Calibration |
1 point |
Calibration Range |
Reading ±10°C |
General Specifications |
|
Temperature Compensation |
0 to 100°C/32 to 212°F, manual or automatic |
Stability Criteria |
Low or high |
Calibration Due Alarm |
1 to 31 days or off |
Auto-Power Off |
10, 20 or 30 minutes after last key pressed |
Memory |
Stores up to 500 data sets |
Output |
USB communication interface |
Connector |
BNC, 6-pin nimi-DIN, 3.5mm jack socket |
Display |
Custom LCD (80×60mm) |
Power |
3×1.5V AA batteries or DC5V power adapter |
Battery Life |
Approximately 150 hours (turn off the backlight) |
Dimensions |
170(L)×85(W)×30(H)mm |
Weight |
300g |
Items | Description |
P11 pH Electrode | For the general applications |
P11-LiCl pH Electrode | For the non-aqueous samples |
P11-HA pH Electrode | For the high alkalines samples |
P11-NA pH Electrode | For the biofuels |
P12 pH Electrode | For the sample in the test tube |
P13 pH Electrode | For the micro-volume samples |
P15 pH Electrode | For the low conductivity samples |
P16 pH Electrode | For the Tris buffers |
P18 pH Electrode | For the slurries and soils |
P19 pH Electrode | For the semisolids |
P21 pH Electrode | For the colloids |
P22 pH Electrode | For the high temperature samples |
501 ORP Electrode | For the sample with strong redox potential |
502 ORP Electrode | For the sample with weak redox potential |
CON-0.1 Conductivity Electrode | For the pure water |
CON-1 Conductivity Electrode | For the general water |
CON-10 Conductivity Electrode | For the high conductivity water |
TP-10K Temperature Probe | For the temperature measurement |
pH Buffer Solutions | 480ml/bottle |