• Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter
  • Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter
  • Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter

Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter

After-sales Service: Online After-Sales Service
Warranty: 1 Year
Display: LCD
Appliance: Medical Research, Biochemistry
Portable: Portable
Certification: CE
Customization:
Gold Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
Bante904-CN
Conductivity Range
0.01~20.00,200.0,2000µs/Cm,20.00,200.0ms/Cm
TDS Range
0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200
Salinity Range
0.00~80.00ppt, 0.00~42.00PSU
Resistivity Range
0.00~20.00mΩ
Temperature Range
0~105°c, 32~221°f
Transport Package
Export Standard Package
Trademark
West Tune
Origin
Shanghai
HS Code
9027900000
Production Capacity
50000/Yeas

Product Description

Bante904-CN Lab Multiparameter Conductivity/ TDS/ DO Water Quality Meter
Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterFEATURES:
CONDUCTIVITY/TDS/SALINITY/RESISTIVITY:
1 to 5 points push-button calibration, automatically recognizes the calibration solutions.
Selectable cell constant (0.1/1/10), normalization temperature (20°C/25°C), TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.

Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter
DISSOLVED OXYGEN:
1 or 2 points calibration using the air-saturated water or zero oxygen solution.
Salinity and barometric pressure compensations provide the reliable measuring results.
Selectable measurement units, including the mg/L, ppm, mmHg and kPa.
GENERAL:
Automatic Temperature Compensation provides accurate reading over the entire range.
Calibration Due Reminder prompts user to calibrate the meter regularly.
Stability indicator shows when a measurement is recognized as stable.
Auto-Hold feature senses and locks the measurement endpoint
Battery indicator shows the remaining battery capacity.
Auto-Power Off effectively conserves battery life.
Calibration report provides the details of the calibration standards and electrode slopes.
Setup menu allows setting the 15 parameters, including the number of calibration points, stability criteria, temperature unit, etc.
Reset feature automatically resumes all settings back to factory default options.
Expanded memory stores and recalls up to 500 data sets.
Stored readings can be transferred into the computer by USB communication interface.
METER INCLUDES:

Bante 904 meter: conductivity electrode, DO probe, temperature probe, conductivity standard solutions, DO electrolyte solution,power adapter.

Specifications:
Model Bante904-CN
Conductivity  
Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Accuracy ±0.5% F.S
Resolution 0.001, 0.01, 0.1, 1
Calibration Points 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm
Temperature Coefficient 0.0~10.0%/°C
Compensation Modes Linear or Pure water
Cell Constant K=0.1, 1, 10 or Custom
Reference Temperature 20°C or 25°C
TDS  
Range 0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt)
Accuracy ±1% F.S
Resolution 0.01, 0.1, 1
TDS Factor 0.1~1.0 (Default 0.5)
Salinity  
Range 0.00~80.00ppt, 0.00~42.00psu
Accuracy ±1% F.S
Resolution 0.01
Measurement Modes Practical salinity (psu) or Natural seawater (ppt)
Resistivity  
Range 0.00~20.00MΩ
Accuracy ±1% F.S
Resolution 0.01, 0.1, 1
Dissolved Oxygen  
DO Range 0.00~20.00mg/L
Accuracy ±0.2mg/L
Resolution 0.1, 0.01mg/L, selectable
% Saturation of Oxygen 0.0~200.0%
Accuracy ±2.0%
Resolution 0.1, 1%
Calibration Points 1 or 2 points
Pressure Correction 60.0~112.5kPa, 450~850mmHg
Salinity Correction 0~50g/L
Temperature  
Range 0~105°C, 32~221°F
Accuracy ±0.5°C
Resolution 0.1°C, 0.1°F
Calibration Points 1 point
Calibration Range Measured value ±10°C
General  
Temperature Compensation 0~100°C, 32~212°F, Manual or Automatic
Data Hold Manual or Auto-Endpoint
Stability Criteria Low or High
Calibration Due Alarm 1 to 31 days or Off
Reset Function Yes
Memory Stores up to 500 data sets
Output USB communication interface
Connector BNC, 6-pin mini plug
Display LCD
Power DC5V, using AC adapters, 220VAC/50Hz
Dimensions 210(L)×188(W)×60(H)mm
Weight 1.5kg

Our Company:
Bante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality MeterBante904-Cn Lab Multiparameter Conductivity/ TDS/ Do Water Quality Meter


Delivery time: usually 3-15 days
Warranty: 12months
Payment methods: T/T, Western Union, Paypal, Credit Card, L/C
 
Our main lab instruments: mixer, shaker, water quality tester, autoclave, incubator, oven, water treatment(PH/DO/COND/Turbidity meter, pure water system), spectrophotometer, refractometer, peristaltic pump, heating mantle, hot plate, PCR machine, homogenizer, water bath and so on.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now