Model |
|
Bante900 |
Bante901 |
Bante902 |
Bante903 |
Bante904 |
pH |
|
|
|
|
|
|
Range |
-2.000~20.000pH |
√ |
√ |
√ |
√ |
/ |
Accuracy |
±0.002pH |
√ |
√ |
√ |
√ |
/ |
Resolution |
0.1, 0.01, 0.001pH, selectable |
√ |
√ |
√ |
√ |
/ |
Calibration Points |
1 to 5 points |
√ |
√ |
√ |
√ |
/ |
pH Buffer Options |
USA, NIST, DIN or Custom |
√ |
√ |
√ |
√ |
/ |
mV |
|
|
|
|
|
|
Range |
±1999.9mV |
√ |
√ |
√ |
√ |
/ |
Accuracy |
±0.2mV |
√ |
√ |
√ |
√ |
/ |
Resolution |
0.1, 1mV, selectable |
√ |
√ |
√ |
√ |
/ |
Calibration Points |
1 point |
√ |
/ |
√ |
/ |
/ |
Measurement Modes |
Relative or Absolute mV |
√ |
/ |
√ |
/ |
/ |
Ion |
|
|
|
|
|
|
Range |
0.001~19999 (Deponding on the range of ISE) |
√ |
/ |
/ |
/ |
/ |
Accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
√ |
/ |
/ |
/ |
/ |
Resolution |
0.001, 0.01, 0.1, 1 |
√ |
/ |
/ |
/ |
/ |
Calibration Points |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
√ |
/ |
/ |
/ |
/ |
Measurement Units |
ppm, mg/L, mol/L, mmol/L |
√ |
/ |
/ |
/ |
/ |
Conductivity |
|
|
|
|
|
|
Range |
0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm |
√ |
√ |
√ |
/ |
√ |
Accuracy |
±0.5% F.S |
√ |
√ |
√ |
/ |
√ |
Resolution |
0.001, 0.01, 0.1, 1 |
√ |
√ |
√ |
/ |
√ |
Calibration Points |
1 to 5 points |
√ |
√ |
√ |
/ |
√ |
Calibration Solutions |
10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm |
√ |
√ |
√ |
/ |
√ |
Temperature Coefficient |
0.0~10.0%/°C |
√ |
√ |
√ |
/ |
√ |
Compensation Modes |
Linear or Pure water |
√ |
√ |
√ |
/ |
√ |
Cell Constant |
K=0.1, 1, 10 or Custom |
√ |
√ |
√ |
/ |
√ |
Reference Temperature |
20°C or 25°C |
√ |
√ |
√ |
/ |
√ |
TDS |
|
|
|
|
|
|
Range |
0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) |
√ |
√ |
√ |
/ |
√ |
Accuracy |
±1% F.S |
√ |
√ |
√ |
/ |
√ |
Resolution |
0.01, 0.1, 1 |
√ |
√ |
√ |
/ |
√ |
TDS Factor |
0.1~1.0 (Default 0.5) |
√ |
√ |
√ |
/ |
√ |
Salinity |
|
|
|
|
|
|
Range |
0.00~80.00ppt, 0.00~42.00psu |
√ |
/ |
√ |
/ |
√ |
Accuracy |
±1% F.S |
√ |
/ |
√ |
/ |
√ |
Resolution |
0.01 |
√ |
/ |
√ |
/ |
√ |
Measurement Modes |
Practical salinity (psu) or Natural seawater (ppt) |
√ |
/ |
√ |
/ |
√ |
Resistivity |
|
|
|
|
|
|
Range |
0.00~20.00MΩ |
√ |
/ |
√ |
/ |
√ |
Accuracy |
±1% F.S |
√ |
/ |
√ |
/ |
√ |
Resolution |
0.01, 0.1, 1 |
√ |
/ |
√ |
/ |
√ |
Dissolved Oxygen |
|
|
|
|
|
|
DO Range |
0.00~20.00mg/L |
√ |
/ |
/ |
√ |
√ |
Accuracy |
±0.2mg/L |
√ |
/ |
/ |
√ |
√ |
Resolution |
0.1, 0.01mg/L, selectable |
√ |
/ |
/ |
√ |
√ |
% Saturation of Oxygen |
0.0~200.0% |
√ |
/ |
/ |
√ |
√ |
Accuracy |
±2.0% |
√ |
/ |
/ |
√ |
√ |
Resolution |
0.1, 1% |
√ |
/ |
/ |
√ |
√ |
Calibration Points |
1 or 2 points |
√ |
/ |
/ |
√ |
√ |
Pressure Correction |
60.0~112.5kPa, 450~850mmHg |
√ |
/ |
/ |
√ |
√ |
Salinity Correction |
0~50g/L |
√ |
/ |
/ |
√ |
√ |
Temperature |
|
|
|
|
|
|
Range |
0~105°C, 32~221°F |
√ |
/ |
√ |
√ |
√ |
Accuracy |
±0.5°C |
√ |
/ |
√ |
√ |
√ |
Resolution |
0.1°C, 0.1°F |
√ |
/ |
√ |
√ |
√ |
Calibration Points |
1 point |
√ |
/ |
√ |
√ |
√ |
Calibration Range |
Measured value ±10°C |
√ |
/ |
√ |
√ |
√ |
General |
|
|
|
|
|
|
Temperature Compensation |
0~100°C, 32~212°F, Manual or Automatic |
√ |
√ |
√ |
√ |
√ |
Data Hold |
Manual or Auto-Endpoint |
√ |
√ |
√ |
√ |
√ |
Stability Criteria |
Low or High |
√ |
√ |
√ |
√ |
√ |
Calibration Due Alarm |
1 to 31 days or Off |
√ |
√ |
√ |
√ |
√ |
Reset Function |
Yes |
√ |
√ |
√ |
√ |
√ |
Memory |
Stores up to 500 data sets |
√ |
√ |
√ |
√ |
√ |
Output |
USB communication interface |
√ |
√ |
√ |
√ |
√ |
Connector |
BNC, 6-pin mini plug |
√ |
√ |
√ |
√ |
√ |
Display |
LCD |
√ |
√ |
√ |
√ |
√ |
Power |
DC5V, using AC adapters, 220VAC/50Hz |
√ |
√ |
√ |
√ |
√ |
Dimensions |
210(L)×188(W)×60(H)mm |
√ |
√ |
√ |
√ |
√ |
Weight |
1.5kg |
√ |
√ |
√ |
√ |
√ |