Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer

Product Details
Customization: Available
After-sales Service: 1 Year
Application: Laboratory Apparatus
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
101~500 square meters
  • Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer
  • Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer
  • Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer
  • Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer
  • Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer
  • Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer
Find Similar Products
  • Overview
  • Product Description
  • More related products
Overview

Basic Info.

Model NO.
4730FG
Warranty
1 Year
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
New Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001
Customized
Customized
Monochromator Type
Czerny - Turner
Grating
1800 Lines/mm
Bandwidth
0.1 Nm,0.2nm,0.4nm,0.7nm,1.0nm,2.0nm Automatic
Wavelength Indication Error
±0.15nm
Wavelength Repeatability
≤ 0.03nm
Absorbance Range
-0.1 ~ 2.5A
Baseline Stability(Cu)
≤0.002A/15min(Static Test)V
Lod(Cu)
0.003μg/Ml
Characteristic Concertration(Cu)
0.02μg/Ml / 1%
Focal Length
Wl: Accuracy ≤ ±0.25nm
Transport Package
Standard Export Package
Specification
190-900nm
Trademark
West Tune
Origin
China
HS Code
9031809090
Production Capacity
10000units/Year

Product Description

Product Description

4730FG Flame graphite furnace Automatic integrated Atomic absorption spectrophotometer
Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer

Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer

Features:
1. Permanently equipped with both flame and graphite furnace atomize, switched by computer. Automatically determine the best position
 
2. Total reflection optical system, using two aspherical optical elements to strictly correct astigmatism, effectively improve the monochromator entrance slit energy
 
3. Vertical 8 light stand, rotating light search by computer control, preheating and optimizing use conditions.
 
4. Automatic wavelength scanning and peaking
 
5. With self-absorption correction and deuter ium lamp correction 2 background deduction methods. when the background signal 1A, deuter ium lamp background correction capability >60 times
 
6. Automatically cut off the gas when the gas pressure is insufficient, the power supply is interrupted, the flame is turned off or the combustion head is not matched, to ensure safety.
 
7. Equipped with HD camera, the automatic graphite furnace injection needle position adjustment is more convenient, the whole process of graphite furnace injection visualization.
 
8. Equipped with waste liquid level sensor to ensure data stability and safe use



Specifications:
Monochromator Type Czerny - turner
Grating 1800 lines/mm
Grating Flare Wavelength 250nm
Wavelength Range 190nm ~ 900nm
Bandwidth 0.1 nm,0.2nm,0.4nm,0.7nm,1.0nm,2.0nm automatic
Wavelength Indication Error ±0.15nm
Wavelength Repeatability ≤ 0.03nm
Absorbance Range -0.1 ~ 2.5a
Baseline Stability(Cu) ≤0.002A/15min(Static test)
Characteristic Concertration(Cu) 0.02μg/ml / 1%
Lod(Cu) 0.003μg/ml
Spectral Bandwidth Deviation(Cu) ≤0.2nm ±0.02nm(bandwidth 0.2nm)
Measurement Repeatability(Cu) ≤0.45%(flame method)
Measurement LOD Cd≤0.2×10-12 g (GF method)
Lamp Stand 8 lamps
Temperature Control 20-3000 ºC,maximum heating rate >2000 ºC/s
Heating Steps 20 steps
Slope Heating Time 0s-999s
Holding Heating Time 1s ~ 999s (The sum of the slope heating time and the holding heating time is not greater than 999s)
Graphite Furnace Temperature Accuracy ±10 ºC
Characteristic Mass Cd≤0.5pg
Measurement Repeatability Cd≤2% (Use automatic sampler and platform graphite tube)
Linear Error Cd ≤10%
Graphite Furnace Heating Method Longitudinal flux induction heating
Burner Titanium burner
Atomizer High efficiency glass atomizer
Premix Chamber Explosion-proof
Power AC220v±22v,50hz±0.5hz, 6600W
Host Instrument 850mm×637mm×575mm

Software functions:
1. Method save and call: Different experimental methods and parameter Settings can be saved. This makes the method switching more convenient during the analytical test, and can also improve the consistency and repeatability of the analytical test.

 
2. Concentration calculation: standard curve method and standard addition method are provided. Standard curve method can choose single point calibration or multi-point calibration, multi-point calibration can choose 1, 2, 3 functions and mutual conversion, support up to 30 concentration points repeated 20 times of standard sample calibration, automatic calculation of average value, standard deviation (SD) and relative standard deviation (RSD)
 
3. Sample information table editing and data processing functions: provide weight factor, volume factor, dilution factor and other sample information editing, can calculate the solid sample concentration (sample content) directly, improve the integrity of the experiment report.
 
4. Data export and report generation: software supports data export capabilities, which can be processed into excel formats, which facilitate statistics and further analysis. At the same time, the software also provides the reporting generation function, which allows users to generate complete experimental reports as required, and the storage and printing is used for recording and filing


Standard Accessories 
1. Oil-free air compressor
2. Hollow cathode lamp (Cu)
3. High efficiency glass atomizer
4. Titanium burner 100mm
5. Oxygen pressure reducing valve
6. Acetylene pressure reducing valve
7. Air water filter
8. Pyrolytic graphite tube
9. Platform graphite tube
10. Micro pipettor


Cu HC Lamps is in the standard confirguration
Other lamps are all optional


Optional Accessories 
AS4030 Graphite furnace automatic sampler
AS800A Cooling water circulator
AAH-1 flow injection hydride generator
Hollow cathode lamps
High efficiency glass atomizer
Graphite tubes
Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer


 
More related products

Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer


Westtune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption SpectrophotometerWesttune 4730fg Aas Metal Analyzer Flame-Graphite Fumace Automatic Integrated Atomic Absorption Spectrophotometer

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier