Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold

Product Details
Customization: Available
After-sales Service: 1 Year
Application: Laboratory Apparatus
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
101~500 square meters
  • Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
  • Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
  • Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
  • Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
  • Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
  • Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
Find Similar Products
  • Overview
  • Product Description
  • More related products
Overview

Basic Info.

Model NO.
AA320N
Detection Method
Spectrophotometer
Advantage
High Resolution
Principle
New Spectrometer
Wavelengths
UV Spectrometer
Dispersive Element
Grating Spectrometer
Light Number
Monochromator
Certification
ISO9001
Customized
Customized
Wavelength Accuracy
≤±0.5nm
Wavelength Repeatability
≤0.3nm (Single Direction)
Spectrum Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Base Line Stability
±0.004ABS/30min
Detection Limit of Coppe
≤ 0.08μg/Ml
RS232
Including
Transport Package
Standard Export Package
Specification
190-900nm
Trademark
West Tune
Origin
China
HS Code
9031809090
Production Capacity
10000units/Year

Packaging & Delivery

Package Size
125.00cm * 80.00cm * 77.00cm
Package Gross Weight
200.000kg
Lead Time
15 days (1 - 5 Pieces)
To be negotiated ( > 5 Pieces)

Product Description

Product Description

AA320N AAS Atomic Absorption Spectrophotometer for Metal Elements tests

Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold
Common Features 
1. Build-in computer data processing and LCD display: stable and reliable with the functions of integral holding, peakheight and area, autozero adjusting, deuterium-lamp background correction, multi-linear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC. 
2. Stability: Double-beam system can automatically compensate the light source drift and wavelengthdrift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. 
3. Quickly: The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples. 
4. High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration. 
5. High energy optical path: A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot, which enters into the slit. Therefore the light flux of double beam is enhanced. 
6. Long-life and anti-corrosive atomization system: The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling. 
7. Multi-functional analysis mode: for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation. 
8. Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze air-acetyleneflame. 
9. Complete set of accessories: to be supplied with the instrument and ready for use after they are purchased.

Specifications
WL range:190-900nm 
WL accuracy: ≤±0.5nm
WL repeatability: ≤0.3nm (single direction)
Spectrum bandwidth: 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution : <40%
Base line stability: ±0.004Abs/30min
Characteristic concentration of copper: ≤ 0.04μg/ml/1%
Detection limit of copper: ≤ 0.08μg/ml
Background calibration ability: Greater than 30 times
RS232: including
Printer: Optional
Power supply: 220V 3A, 50Hz
G.W.: 138Kg / 56Kg 
Package size: 1250mmx795mmx765mm (Main instrument)   545mmx445mmx1385mm ( Accessories ) 

Standard Accessories 
Oil-free air compressor 
Glass Atomizer 
Cu Hollow cathode lamp 
Atomizer unit 
Burner unit 
Dust cover 
Water-separating gas filter 
Titanium burner---10cm 

Optional Accessories 
Model GA3202 HGA graphite furnace system 
Hydride generator 
Hollow cathode lamp 
Graphite tubes 
Software 
Recirculating cooling water system 


Model GA3202 HGA graphite furnace system 
1. Heating steps: 9 steps 
2. Temperature range (nominal Temperature): 20 t= -3000"C 
3. Slope heating time: 0-999s 
4. Heating holding time: 1 s-999s (the sum of both time should be less than 999 seconds) 
5. Inert gas needed: argon, pressure of entry larger than 0.3Mpa 
6. Cooling water: tap water or cycling water, flow rate no less than 2L/min 
7. Output: LCD 
8. Gas pressure alarm, furnace overheated alarm 
9. Interface with Atomic absorption spectrophotometer, autosampler and RS232 
10. High-power temperature heating function (1000 "C -2700 "C ) 
11. Test sample together with atom absorption equipment. Cd :S1x10-12g;Cu s1 x10-10g 
12. Working Conditions: 
      Power source: 220V:t22V, 50Hz:t1 Hz, 3A 
                              220VI22V, 50Hz:t1Hz, 30A 
      Power: 5.1 kW for 220V on about 2700 "C 
      Ambient temperature: +10"C-+30"C 
      Relative humidity: less than 85% 
      Instrument rating power: 7.2kW


Packing list
Item. Descriptions Qty.
1   Main instrument 1
2   Power cable 1
3   Operating manual 1
4   Burner unit 1
5   Water-separating gas filter base 1
6   Bush 10
7   Threaded sleeve 10
8   Dust cover 1
9   Gasket 15
10   Sheet gasket 4
11   Scale plate for adjust the light 1
12   Joint 1
13   Pul-out piece spring 1
14   Input Joint 1
15   Output Joint 1
16   Closure head 2
17   Hand knob 1
18   Scale disk 1
19   Acetylene Regulator YQE-213 1
20   Water-separating gas filter QSL1/4' 1
21   PU plastic tube Φ6*1 15M
22   PVC tube Φ10*1.4 3M
23   O gland ring D10*2 10
24   O gland ring D16*2 4
25   O gland ring D32*3 6
26   O gland ring D40*3 6
27   Fuse 2A 5
28   Fuse 0.5A 5
29   Fuse 0.1A 5
30   Nut runner 4
31   Tools 1
32   Glass Atomizer 1
33   Hollow cathode lamp Cu 1
       
 
More related products

Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold


Westtune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for GoldWesttune Metal Elements Analysis Atomic Absorption Spectrophotometer Model AA320n for Gold

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier