Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter

Product Details
Customization: Available
After-sales Service: Online Aftersales Service
Warranty: 1year
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
2000000 RMB
Plant Area
101~500 square meters
  • Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter
  • Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter
  • Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter
  • Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter
  • Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter
  • Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter
Find Similar Products

Basic Info.

Model NO.
Biolum-III
Detection Limit
1*10-16 Moles ATP
Detection Range
0-999999rlus
Detection Deviation
±5% or ±5ruls
Self-Calibration at Startup
30s
Real-Time Detection Time
10s Per Test
Storage Capacity
10000 Results
Transport Package
Carton Box
Specification
189*70*36 mm
Trademark
WESTTUNE
Origin
China
Production Capacity
50units/Week

Product Description

Biolum-III ATP Hygiene Monitoring System
Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterSummary:
Biolum III Portable ATP Hygiene Monitoring System, a powerful tool for implementing and managing your hygiene monitoring program.
Taking advantages of the progressive QuickSwarb surface test, the hygiene level of the tested surface will be evaluated in seconds, and the results can be visualized on screen. Featuring the state-of-art technology, the BioLumIII is a user-friendly, flexible, and accurate quality monitoring system. It has all the features to maximize its value to your business.

Technical parameters

ITEMS
PARAMETER
Biolum-III
Dimensions
189*70*36 mm
Weight
≤300g
Detection limit
1*10-16 moles ATP
Detection Range
0-999999RLUs
Detection Deviation
±5% or ±5RULs
Self-calibration at startup
30s
Real-time detection time
10s per test
Programmable Test Locations
255 programmable test points per test plan
Storage Capacity
10000 results
Communication interface
USB, Bluetooth
Reproducibility
CV 8%-20%
Correlation Coefficient
R2 ≥0.99
Power Supply
Rechargeable battery
Running Time
continuously work for >8 hrs, standby for >600hrs
Temperatures allowed during operation
5-40ºC
Relative humidity allowed during operation
20-80%
QuickSwab
Swab strotage
-10~ -20ºC 12months, 2~8ºC 3 months'
Swab compatible
Biolum-II, Biolum-III Hygiena SystemSURE Plus, EnSURE, Others


Method Comparison:
Compare with the traditional cell culture method, ATP hygiene monitoring system is the method that combines quantitative data collection with scientific measurement and still delivers speed result.

 

Compared Items
ATP Detection
based on BioLum-III
Conventional Bacteria Culture/Plating
Microorganism
All Bacteria, Fungi, Algae.
Only the specific bacteria that grow on the culture media (Normally the LB agar culture can only detect aerobic bacteria).
Aerobic bacteria
Autotrophic heterotrophic
bacteria
×
Acetobacter
×
Nitrite bacteria
×
Mycete
Algae
×
Detection Time
10 sec
1-5 days
Operation
simple, less steps, only
one reagents is needed
The conditions that medium and detection needed are required, complicated operation, a variety of human factors may affect the result.
Result
rapid, pre-alert and traceable
processing lags, the result can be reserved for a long time and for further detection.
Combined with two methods, utilize ATP detection method for contamination detection
and conventional culture method to detect the species of bacteria and the contamination sources.


Food Processors
1. Cleaning control the process of production and processing
2. Evaluating the disinfection of packaging
3. Testing the microbes of finished products and material
4. Monitoring the hygiene of processing environment

Food Service
1. Cleanliness control of the kitchen, dishes, operating carton and tools
2.Evaluating disinfection of dishes
3.Disinfection control of the airline catering dishes
4.Hygiene supervision for quality control department

Health Care
1. Objects superficial inspection of the hospital major department
2. Hand cleaning check of the medical staffs
3. Medical equipment cleanliness and disinfection inspection
4. Cleanliness testing of the hospital environment

Environment protection
1. Evaluating biological pollution of the water and wastewater sample
2. Detecting the contaminating microorganisms of soil, activated sludge samples and so on.

Other Industries
1. Daily health products manufacture
2. Quality supervision department
3. Hospitality industry hygiene management
4. The port supervision etc.


Real pictures for your reference:
Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP Meter

 

Westtune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterWesttune Biolum-III Best Selling Portable ATP Bacteria Meter ATP Hygiene Monitoring System with USB Interface ATP MeterDelivery time: usually 3-15 days
Warranty: 12months
Payment methods: T/T, Western Union, Paypal, Credit Card, L/C
 
Our main lab instruments: mixer, shaker, water quality tester, autoclave, incubator, oven, water treatment(PH/DO/COND/Turbidity meter, 
pure water system), spectrophotometer, refractometer, peristaltic pump, heating mantle, hot plate, PCR machine, homogenizer, water bath and so on.

ally 3-15 days
Warranty: 12months
Payment methods: T/T, Western Union, Paypal, Credit Card, L/C
 
Our main lab instruments: mixer, shaker, water quality tester, autoclave, incubator, oven, water treatment(PH/DO/COND/Turbidity meter, 
pure water system), spectrophotometer, refractometer, peristaltic pump, heating mantle, hot plate, PCR machine, homogenizer, water bath and so on.
Technical ParDelivery time: usually 3-15 days
Warranty: 12months
Payment methods: T/T, Western Union, Paypal, Credit Card, L/C
 
Our main lab instruments: mixer, shaker, water quality tester, autoclave, incubator, oven, water treatment(PH/DO/COND/Turbidity meter, 
pure water system), spectrophotometer, refractometer, peristaltic pump, heating mantle, hot plate, PCR machine, homogenizer, water bath and so on.ameter

Features


Features

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier