Product Description
4730FG Atomic absorption spectrophotometer
Flame graphite furnace all-in-one machine //
Automatic integrated
Features:
1. Permanently equipped with both flame and graphite furnace atomize, switched by computer. Automatically determine the best position
2. Total reflection optical system, using two aspherical optical elements to strictly correct astigmatism, effectively improve the monochromator entrance slit energy
3. Vertical 8 light stand, rotating light search by computer control, preheating and optimizing use conditions.
4. Automatic wavelength scanning and peaking
5. With self-absorption correction and deuter ium lamp correction 2 background deduction methods. when the background signal 1A, deuter ium lamp background correction capability >60 times
6. Automatically cut off the gas when the gas pressure is insufficient, the power supply is interrupted, the flame is turned off or the combustion head is not matched, to ensure safety.
7. Equipped with HD camera, the automatic graphite furnace injection needle position adjustment is more convenient, the whole process of graphite furnace injection visualization.
8. Equipped with waste liquid level sensor to ensure data stability and safe use
Specifications:
Monochromator Type |
Czerny - turner |
Grating |
1800 lines/mm |
Grating Flare Wavelength |
250nm |
Wavelength Range |
190nm ~ 900nm |
Bandwidth |
0.1 nm,0.2nm,0.4nm,0.7nm,1.0nm,2.0nm automatic |
Wavelength Indication Error |
±0.15nm |
Wavelength Repeatability |
≤ 0.03nm |
Absorbance Range |
-0.1 ~ 2.5a |
Baseline Stability(Cu) |
≤0.002A/15min(Static test) |
Characteristic Concertration(Cu) |
0.02μg/ml / 1% |
Lod(Cu) |
0.003μg/ml |
Spectral Bandwidth Deviation(Cu) |
≤0.2nm ±0.02nm(bandwidth 0.2nm) |
Measurement Repeatability(Cu) |
≤0.45%(flame method) |
Measurement LOD |
Cd≤0.2×10-12 g (GF method) |
Lamp Stand |
8 lamps |
Temperature Control |
20-3000 ºC,maximum heating rate >2000 ºC/s |
Heating Steps |
20 steps |
Slope Heating Time |
0s-999s |
Holding Heating Time |
1s ~ 999s (The sum of the slope heating time and the holding heating time is not greater than 999s) |
Graphite Furnace Temperature Accuracy |
±10 ºC |
Characteristic Mass |
Cd≤0.5pg |
Measurement Repeatability |
Cd≤2% (Use automatic sampler and platform graphite tube) |
Linear Error |
Cd ≤10% |
Graphite Furnace Heating Method |
Longitudinal flux induction heating |
Burner |
Titanium burner |
Atomizer |
High efficiency glass atomizer |
Premix Chamber |
Explosion-proof |
Power |
AC220v±22v,50hz±0.5hz, 6600W |
Host Instrument |
850mm×637mm×575mm |
Software functions:
1. Method save and call: Different experimental methods and parameter Settings can be saved. This makes the method switching more convenient during the analytical test, and can also improve the consistency and repeatability of the analytical test.
2. Concentration calculation: standard curve method and standard addition method are provided. Standard curve method can choose single point calibration or multi-point calibration, multi-point calibration can choose 1, 2, 3 functions and mutual conversion, support up to 30 concentration points repeated 20 times of standard sample calibration, automatic calculation of average value, standard deviation (SD) and relative standard deviation (RSD)
3. Sample information table editing and data processing functions: provide weight factor, volume factor, dilution factor and other sample information editing, can calculate the solid sample concentration (sample content) directly, improve the integrity of the experiment report.
4. Data export and report generation: software supports data export capabilities, which can be processed into excel formats, which facilitate statistics and further analysis. At the same time, the software also provides the reporting generation function, which allows users to generate complete experimental reports as required, and the storage and printing is used for recording and filing
Standard Accessories
1. Oil-free air compressor
2. Hollow cathode lamp (Cu)
3. High efficiency glass atomizer
4. Titanium burner 100mm
5. Oxygen pressure reducing valve
6. Acetylene pressure reducing valve
7. Air water filter
8. Pyrolytic graphite tube
9. Platform graphite tube
10. Micro pipettor
Cu HC Lamps is in the standard confirguration
Other lamps are all optional
Optional Accessories
AS4030 Graphite furnace automatic sampler
AS800A Cooling water circulator
AAH-1 flow injection hydride generator
Hollow cathode lamps
High efficiency glass atomizer
Graphite tubes
More related products