A131 Laboratory Benchtop Professional ORP/ Ion/ Water Hardness Test Meter
MEASUREMENT PARAMETERS
A131 meter: Ion Concentration, Water Hardness, mV, Temperature
FEATURES
ORP:
1 point offset calibration allows adjusting the displayed value to a known standard.
Relative and absolute millivolt modes provide the reliable ORP measurements.
ION:
Selectable ion measurement methods, including the direct reading, known addition, known
subtraction, sample addition and sample subtraction.
Selectable concentration units, including the ppm, mg/L, mol/L and mmol/L.
2 to 5 points calibration, providing the 8 concentration points can be selected.
Automatically recognizes the ion selective electrodes, does not need to specify type of ion.
Electrode management is capable of storing the 3 slopes and recalling the calibration data
of each electrode.
Calibration report provides the details of the calibration standard and slope.
WATER HARDNESS:
2 to 5 points calibration from low to high concentrations.
Selectable measurement units ( German degree, English degree, French degree, mg/L and
mmol/L) are used for professional water hardness measurements
GENERAL:
Calibration Due Reminder prompts user to calibrate the meter regularly.
Stability indicator shows when a measurement is recognized as stable.
Auto-Read feature senses and locks the measurement endpoint.
Interval Readings automatically send the measurement data to the computer or printer.
Password protection prevents the unauthorized calibration and settings.
Expanded memory stores and recalls up to 1000 data sets.
Stored readings can be transferred into the computer by USB communication interface.
Reset feature automatically resumes all settings back to factory default options.
METER INCLUDES
A131 meter: ion selective electrode, temperature probe, standard solutions, electrode holder, power adapter.
Optional Electrodes: NH4, Br, Ca, CL, CN, F, NO3, Ag, Na, Cd, Cu, I, Pb, K, S
A131-CN cyanide ion meter does not provide standard solution
Specifications:
Model |
A131 |
mV |
|
Range |
±2000.0mV |
Accuracy |
±0.2mV |
Resolution |
0.1mV |
Ion |
|
Range |
0.001~30000 (Deponding on the range of ISE) |
Accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Resolution |
0.001, 0.01, 0.1, 1 |
Calibration Points |
2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) |
Measurement Units |
ppm, mg/L, mol/L, mmol/L |
Measurement Methods |
Direct reading, known addition, known subtraction, |
|
sample addition, sample subtraction |
Water Hardness |
|
Range (Concentration) |
0.05~200mmol/L |
Range (German Degree) |
0~1120°dH |
Range (English Degree) |
0~1404°e |
Range (French Degree) |
0~2000°fH |
Range (CaCO3) |
0~19999mg/L |
Range (CaO) |
0~11220mg/L |
Range (Ca2+) |
0~8000mg/L |
Accuracy |
±1% F.S |
Resolution |
0.001, 0.01, 0.1, 1 |
Calibration Points |
2 to 5 points |
Calibration Solutions |
0.01, 0.1, 1, 10, 100mmol/L |
Temperature |
|
Range |
0~105°C, 32~221°F |
Accuracy |
±0.5°C |
Resolution |
0.1°C, 0.1°F |
Calibration Points |
1 point |
Calibration Range |
Measured value ±10°C |
General |
|
Temperature Compensation |
0~100°C, 32~212°F, Manual or Automatic |
Data Hold |
Manual or Auto-Endpoint |
Stability Criteria |
Standard or High-accuracy |
Calibration Due Alarm |
1 to 31 days or Off |
Interval Readings |
10, 30, 60 seconds, 10, 30 minutes or Off |
Password Protection |
Yes |
Reset Function |
Yes |
Memory |
Stores up to 1000 data sets |
Output |
USB communication interface |
Connector |
BNC |
Display |
7 inch TFT LCD |
Power |
DC12V, using AC adapter, 220VAC/50Hz |
Dimensions |
240(L)×220(W)×80(H)mm |
Weight |
1.7kg |
Our Company:
Delivery time: usually 3-15 days
Warranty: 12months
Payment methods: T/T, Western Union, Paypal, Credit Card, L/C
Our main lab instruments: mixer, shaker, water quality tester, autoclave, incubator, oven, water treatment(PH/DO/COND/Turbidity meter, pure water system), spectrophotometer, refractometer, peristaltic pump, heating mantle, hot plate, PCR machine, homogenizer, water bath and so on.